Products

Accuniq BP850 Dual Arm Blood Pressure Monitor

Blood Pressure Monitors Range

World’s first dual-arm Automatic sphygmomanometer system that measures blood pressure from both arms to provide convenient and reliable blood pressure measurements.

Measuring both arms gives Systolic Blood Pressure, Diastolic Blood Pressure, Mean Blood Pressure, Pulse, Pulse Wave Pattern, Evaluation of Blood Pressure, Inter Arm Pressure Difference. The BP850 blood pressure monitor can also be set to take 3 measurements in a row to ensure accuracy and at the end, it displays the average blood pressure measurement. The BP850 blood pressure monitor having the ability to measure both arms simultaneously is important in diagnosing underlying vascular disease. A significant difference in the pressure recorded in the right and left arms can signal circulatory problems that may lead to stroke, peripheral artery disease, or other cardiovascular problems.

The measurement is started by pressing a foot pedal, so the patient can measure their blood pressure whilst in the waiting room and then give the print out to the clinician. However, BP850 blood pressure monitor can measure one arm or both arms simultaneously and the results include -Measuring one arm gives Systolic Blood Pressure, Diastolic Blood Pressure, Mean Blood Pressure, Pulse, Pulse Wave Pattern, Evaluation of Blood Pressure

https://www.accuniq.com/bp850/?lang=en/

Diverse Range of Options

  • VIVIS Manager
  • A4 Results Sheet
  • Adjustable chair
Download Catalogue

Specifications

Details

Model

ACCUNIQ BP850

Measuring Method

Oscilometric

Display Mode

Color LCD Touch Display (7 inch)

Measuring Parts

Left • Right • Both arms

Measuring Ranges

Pressure 30~300 mmHg, Pulse 30-240 bpm

Accuracy

Pressure ±3mmHg, Pulse Within ±3%

Cuff Type

Double cuff with automatic pressurization

Resolution

1 mmHg

Pressurizing Method

Automatic pressurization by DC-MOTOR

Method of exhaust

Micro-controlled electronic exhaust type

Pressurizing Time

Approx. 20 seconds per pressurization

Measuring Time

Approx. 50 seconds per measurement

Power Consumption

Input AC 100~240V, 50/60 Hz | Output DC 12V, 5A adaptor

Data Transmission

RS-232C, USB cable

Operating Range

Temperature 10~40°C (50°F~140°F), Humidity 30~75%

Storage Environment

Temperature -10~60°C (-50°F~140°F), Humidity lower than 95%

Dimension

530(W) x 481(D) x 319(H)mm

Weight

Approx. 26.5lb • 12kg

Printer

High speed thermal printer

Function

Sensor for detecting arm – Left • Right

Memory – Comparing previous and current results

Safety function – Emergency stop button

Optional Equipment

Height adjustable chair, A4 result sheet, data management program

Result Contents

Measuring one arm Systolic Blood Pressure, Diastolic Blood Pressure, Mean Blood Pressure, Pulse, Pulse Wave Pattern, Evaluation of Blood Pressure

Measuring both arms Systolic Blood Pressure, Diastolic Blood Pressure, Mean Blood Pressure, Pulse, Pulse Wave Pattern, Evaluation of Blood Pressure, Inter Arm Pressure Difference